Y-adapter designed to simplify fiber-to-the-home cabling installs

June 25, 2014
Clearfield’s adapter can be used with its mircoduct and pushable fiber to deliver a two-fiber plug-and-play solution in a single pathway.

Clearfield Inc. recently added the FieldShield Hardened Pushable Connector Y-Adapter to its FieldShield product line. The Y-adapter is optimized for use with the company’s FieldShield Microduct and Pushable Fiber, it said. “The FieldShield Y-Adapter reduces initial FTTH [fiber-to-the-home] fiber build-out costs by allowing the provider to distribute a two-fiber plug-and-play solution in a single microduct pathway to a dedicated service access point along the customer lot line” Clearfield explained.

“The FieldShield Y-Adapter is deployed in two stages: the Adapter Kit and Turn-up Kit,” the company continued. “The FieldShield Bulkhead Kit provides a LC adapter in a small re-enterable bulkhead, which can be direct-buried or deployed fully ready for future deployment in an OSP [outside-plant] access enclosure of choice. When customer service requires turn-up, the FieldShield Service Turn-up Kit completes the protected sealed housing, accepting up to two FieldShield LC drop cables which can be deployed independently.”

Johnny Hill, chief operation officer for Clearfield, added, “Building the access-ready-only portion of the network in both greenfield and brownfield environments greatly minimizes the disruption impact on a neighborhood while maximizing the service provider’s people and resources during the construction process. Because the solution is plug-and-play, the post-construction phase of subscriber turn-up is a de-skilled one that reduces the cost of deployment and improves service turn-up time.”

The company also explained how the Y-adapter works, as follows: An environmentally sealed housing—which includes an outer and inner collar, inner housing, grommet and plug—allows for drops to be placed above- or below-ground in harsh environments. Easily accessed from the below-grade enclosure of choice, the Y-adapter provides the components to split a FieldShield Dual LC drop cable into two simplex LC cables. If a network has limited fiber available, the Y-adpater allows the FieldShield Multiport SmarTerminal, configured with a 1x16 splitter, to be fed with a single fiber.

FieldShield Microduct completes the pathway to the customer premises, Clearfield added.

Sponsored Recommendations

imVision® - Industry's Leading Automated Infrastructure Management (AIM) Solution

May 29, 2024
It's hard to manage what you can't see. Read more about how you can get visiability into your connected environment.

Adapt to higher fiber counts

May 29, 2024
Learn more on how new innovations help Data Centers adapt to higher fiber counts.

Going the Distance with Copper

May 29, 2024
CommScopes newest SYSTIMAX 2.0 copper solution is ready to run the distanceand then some.